NMR MAGNETIC FIELD CAMERA
MFC2046
Metrolab’s new generation of magnetic field camera is based on precise pulsed-wave NMR technology.
The miniaturized probe produces high-density probe arrays, to map any pre-clinical, extremity or whole-body MRI magnet as well as any NMR spectroscopy magnet.
Cameras to map any magnet
Probe-array geometries. The classic Metrolab design – MFC9046 – supports any spherical DSV from 150 mm to 600 mm. The new MFC9146 maps cylindrical DSVs as small as 10 mm in diameter and 28 mm in length.
Extended rangeThe range of a probe is defined by the minimum and maximum field strength it can measure. On an instrument,... More and unbeatable precisionPrecision is how closely multiple measurements will be clustered. Also called reproducibility or repeatability. In everyday speech, often confused with... More
Maps magnetic fields from 200 mT to 25.8 T (1 GHz) at a precisionPrecision is how closely multiple measurements will be clustered. Also called reproducibility or repeatability. In everyday speech, often confused with... More of 10 ppbParts per billion, or 10-9. 1 ppb is 10-7 % - not very much at all! More (0.01 ppmParts per million, or 10-6. Bigger than a ppb, but still pretty darn small. More).
RampingThe process of injecting current to bring the field up to the operational field. Used particularly for superconducting magnets. More then mappingThe process of measuring magnetic field intensity at many different points, in order to understand the structure of the field... More
By including a wide-range probeThe actual sensor that is placed in the magnetic field. The NMR probe contains the NMR sample; the Hall probe... More in the middle of the probe arrayFor Metrolab's Magnetic Field Camera, the probe array is a semi-circular plate holding up to 32 NMR probes. More, the magnet may be followed during rampingThe process of injecting current to bring the field up to the operational field. Used particularly for superconducting magnets. More and mapped with just one fixtureSee jig. More.
High tolerance to field gradientIn this context, gradient refers to the spatial variation of the magnetic field. More
The robust system searches and detects the NMRNuclear Magnetic Resonance. A resonance phenomenon seen when you irradiate a sample in a magnetic field with an RF field.... More signal in a gradientIn this context, gradient refers to the spatial variation of the magnetic field. More of 1.35 mT/cm in a 1T field (1350 ppmParts per million, or 10-6. Bigger than a ppb, but still pretty darn small. More/cm).
Request product information
About Metrolab
Established in 1985, Metrolab Technology SA is a Swiss company based in Geneva. We are the global market leader for the development and manufacture of precisionPrecision is how closely multiple measurements will be clustered. Also called reproducibility or repeatability. In everyday speech, often confused with... More magnetometers, which are used to measure high-intensity magnetic fields to a very high degree of precisionPrecision is how closely multiple measurements will be clustered. Also called reproducibility or repeatability. In everyday speech, often confused with... More.
About the technology
MRI and NMRNuclear Magnetic Resonance. A resonance phenomenon seen when you irradiate a sample in a magnetic field with an RF field.... More spectroscopy applications require a highly uniformSee homogeneous. More magnetic field. NMRNuclear Magnetic Resonance. A resonance phenomenon seen when you irradiate a sample in a magnetic field with an RF field.... More is the only magnetic measurement technology capable of generating a magnetic field map with a high degree of precisionPrecision is how closely multiple measurements will be clustered. Also called reproducibility or repeatability. In everyday speech, often confused with... More.